The Honest Answer Up Front
A noise is a symptom with a location, a rhythm and a moment — and those three coordinates narrow the diagnosis faster than any meter. Location: is the sound born at the furnace cabinet, or in the ductwork downstream, or at the thermostat? Rhythm: does it happen once at burner ignition, repeatedly through the cycle, only at start-up, or continuously? Moment: when in the sequence — the click of the ignitor, the whoosh of ignition, the ramp of the blower — does it arrive? Between those three coordinates and the table in the next chapter, you can usually name the culprit before anyone charges you anything.
The urgency sort, because it matters more than the diagnosis sort: metal-on-metal scraping means shut the furnace off now and book the repair — the blower is destroying itself and the bill grows with every cycle. A bang or boom at ignition means stop using it until a licensed gas fitter looks at it — that is delayed ignition, and while many furnaces run years with it, it is a combustion event that belongs to professionals. Rumbling during burner operation gets a same-week call. Everything else — squealing, clicking, humming, duct popping — is scheduled-service territory where a few days of patience cost you nothing but sleep quality.
The economics, stated once and then applied throughout: the $89 diagnostic is credited in full to any completed repair, most noise-caused repairs land between $180 and $650 (capacitors, bearings, motors, ignitors, burners), and the $129 annual tune-up exists precisely because most of these noises are end-states of measurable decline — a capacitor drifting, a bearing drying, a burner filming — that a tune-up catches while it is still a line item on a report instead of a sound in your hallway. If your furnace is already speaking fluently, read on; the table below is the dictionary.
0 sounds that matter
Banging, squealing, rumbling, clicking, humming and scraping. Every furnace complaint we hear is one of these six or a combination, and each has a short list of honest suspects.
0 sound = shut it off
Metal scraping on metal — the blower wheel is loose, broken or chewing its housing. Every minute it runs is machining damage into parts that were fine yesterday.
0 diagnostic, credited
The metered diagnosis that tells you which suspect is guilty. Credited in full against any completed repair, and most noise repairs land in the $180-$650 band.
0 typical response
No-heat and alarming-noise calls across Vancouver, Burnaby and Richmond, 24/7 through heating season; flat $150 after-hours premium disclosed up front.
The Sound-to-Cause Table (Start Here)
Print this, screenshot it, or read it to the dispatcher on the phone — half the value of a noise description is that it lets the right parts go on the truck. Urgency column definitions: NOW means shut it down and call; THIS WEEK means call today-ish; SEASON means book within the month; MONITOR means watch and document.
Two notes on using the table honestly. First, sounds stack: a furnace can bang at ignition from delayed ignition AND squeal from bearings in the same week, and the urgent row always wins the phone call — deal with the combustion story before the comfort story. Second, the table names the most likely cause, not the only one: a hum-with-no-start is usually a capacitor, but the meter decides, which is why the $89 diagnostic exists and why it is credited to the repair when the meter confirms the guess.
Costs in the right-hand column are the honest bands for each repair as we quote them, parts and labour, diagnostic credited. The rows at $0 exist because some of the loudest furnace complaints in this region cost nothing to fix — a duct pop and a cooling tick-tick are the machine and the metal doing what metal does, and knowing which rows are free is worth as much as knowing which rows are urgent.
| Sound | Most likely cause | Urgency | Typical cost |
|---|---|---|---|
| BANG at ignition | Delayed ignition of burners | Stop use, call now | $180-$650 burner service |
| BANG mid-cycle, from ducts | Duct oil-canning, expansion | Season | $0-$250 duct fixes |
| Squeal or screech, continuous | Blower bearings or belt | This week | $180-$450; belts less |
| Rumble during burner run | Dirty burners, gas pressure | This week | $180-$650 combustion service |
| Clicking, repeated | Ignitor or flame sensor retry | Season to this week | Sensor incl. in $129 tune-up |
| Hum, blower will not start | Run capacitor weak or dead | This week | $180-$350 with capacitor |
| Metal scraping on metal | Blower wheel loose or broken | Shut off NOW | $300-$650 wheel/motor |
| Vibration hum at cabinet | Inducer motor bearings | Season to this week | $350-$650 inducer |
| Tick-tick from ducts after cycle | Sheet metal contraction | Monitor | $0 |
Furnace noises mapped to causes and urgency — the field version our dispatchers use.
The Bang at Ignition: Delayed Ignition (Stop Using It)
This is the bang that arrives a second or two after you hear the ignitor click — a muffled boom from the burner compartment, sometimes strong enough to register in the ductwork and rattle the cold-air returns, and homeowners describe it perfectly: "like someone slammed a book shut inside the furnace." The mechanism is delayed ignition: gas flows to the burners, the ignitor or pilot is slow or mispositioned to light it, a small cloud of gas accumulates for that second or two, and when flame finally catches, the cloud lights all at once. A furnace doing this once per ignition is having a small controlled explosion per cycle, and no sentence about furnaces should contain that phrase comfortably.
Why it happens, in the order we find it: dirty or misaligned burners directing gas away from the ignitor; a failing hot-surface ignitor that reaches temperature late; a pilot flame too lazy to catch the cross-lighter on older units; or gas pressure off spec. Metro Vancouver's shoulder seasons contribute — a furnace that idles through our mild October and then runs hard in November accumulates combustion film exactly where it matters, which is why the first real cold snap is bang season in this region. The pattern to watch for: it usually worsens, and the boom that cracked a heat exchanger was almost never the first boom that furnace made.
What to do: stop running it, and call a licensed gas fitter — in BC this is squarely gas-ticket work, not DIY, and it is also the noise on this list with the clearest safety adjacency: repeated delayed ignition is a rollout risk, and rollout is a flame where flame should not be. The professional fix is burner cleaning and alignment, ignitor assessment and combustion verification with an analyzer — the same combustion-side work included in the $129 tune-up, which is the honest context: this noise is a tune-up line item that waited too long. If a burner service clears it, expect the $180 to $650 band; if it has cracked anything on its way out, the conversation moves to our repair-versus-replace guide.
The Bang in the Ducts: Oil-Canning (Annoying, Not Alarming)
The other bang is the friendly twin: a single pop or boom from the ductwork — often the basement main trunk or a long sheet-metal run — arriving as the blower ramps up or as warm air first hits cold metal, and repeating with a rhythm that matches the furnace cycles rather than the ignition instant. This is oil-canning: flat spans of duct sheet metal flexing as pressure and temperature change them, popping through their neutral shape like the bottom of an oil can. It is loud enough to wake people, structural enough to feel in the floor above, and functionally harmless — the duct is complaining about physics, not failing.
Why some houses and not others: it is a construction-era story. Townhouse and subdivision builds from the 1970s through 1990s — and we could draw a map of them across Surrey, Coquitlam and New Westminster — used long flat trunk ducts with wide unsupported spans, exactly the geometry that oil-cans. Tighter blower airflow makes it louder, which is why the noise often appears after a filter upgrade (higher static pressure flexes the metal harder) or a furnace replacement that moved more air than the old one. Colder weather makes it louder too: bigger temperature swings, bigger flex.
The fixes, in escalating order of permanence: wait it out (many homes get one loud week per November and then the ducts settle); add a return-air path or check the filter if the static pressure has crept up; or have the ducts stiffened — a technician creases the flat spans or adds a simple angle brace, which converts the oil-can geometry into something rigid, typically inside a $250-or-less service line. What does not work: stuffing insulation against the duct (it dampens the sound while hiding real problems), and ignoring a bang that is getting rhythmic and per-cycle rather than once-per-startup — that is the ignition bang above, and the distinction is worth a phone call if you are unsure.
Squealing: Bearings, Belts and the Pre-1990 Relics
The squeal is the most distinctive noise in this guide — a continuous screech or whine that tracks the blower speed, rising when the fan ramps, present through the whole cycle, and impossible to ignore in a quiet hallway. In a modern furnace the cause is almost always blower bearings: the direct-drive motor's sealed bearings dry out as the motor ages, first singing only at start-up during cold snaps, then graduating to a constant accompaniment. The arc is predictable and worth taking seriously — bearing noise is a countdown, and the motor that squeals through November seizes or drags by February, usually on the coldest night the season offers, which is a correlation our dispatch board can prove from fifteen years of call logs.
The belt-era variant belongs to the older stock: furnaces from before the early 1990s — and this region keeps thousands of them alive in East Vancouver character homes and older North Vancouver builds — drove their blowers with a V-belt, and a glazed, cracked or simply loose belt screams exactly like bad bearings. The honest differential test: a belt squeal changes pitch with load and sometimes quiets as the system warms; bearing squeal is steadier and follows motor speed alone. Belts are a same-visit repair at the friendly end of the pricing; bearing-driven motor replacement on a direct-drive unit runs into the $650-plus territory where the age of the furnace starts mattering to the math.
What the squeal is NOT, so we can retire two common fears: it is not gas (gas problems rumble and boom, they do not whistle), and it is not a crisis-in-progress — you generally have days to weeks, not minutes. But it is never self-healing, and the affordable window is early: a motor we catch at first squeal is sometimes savable with bearing-era maintenance; a motor we meet at seizure takes the blower wheel and sometimes the control board with it. If the furnace is fourteen-plus years old and the squeal has been around a while, the visit is also the right moment for the repair-versus-replace math, covered honestly in our furnace life expectancy guide.
Rumbling: The Burner Conversation
A rumble is lower than a bang and rounder than a hum — a sustained gravel-voiced vibration during burner operation, felt in the floor near the furnace as much as heard, and stopping when the burners stop even if the blower keeps running. That last detail is the diagnosis: noise that tracks the FLAME is a combustion-side problem, and in this climate it is most often dirty burners — ports partially plugged by years of film and the occasional insect mud-dauber souvenir, so the flame pattern goes ragged and the burners growl. The second suspect is gas pressure out of spec, which changes flame character the same way; the third, on older natural-draft units, is a draft problem — a chimney or B-vent that is not pulling like it should, making the flame lazy and noisy.
Why we treat rumbling as a this-week call rather than a season call: it is a combustion-efficiency and combustion-safety symptom at the same time. Ragged flames make carbon monoxide readings and efficiency numbers worse in the same direction, and while a rumbling furnace is rarely an emergency, it is a furnace asking for its burner service before the deep of winter doubles its workload. The service is licensed-gas-fitter territory end to end: burner pull and clean, flame alignment, manifold pressure measured against the nameplate, and a combustion analysis before and after so the fix is a number, not a vibe. That is the same scope the $129 tune-up includes, which is why rumbling that arrives between tune-ups is simply an early booking signal.
The rumble with a smell deserves its own sentence: if the rumbling arrives with any burnt, formaldehyde-ish, or exhaust-like odour at the registers or around the furnace, the urgency jumps — odour plus combustion noise means products are going somewhere they should not, and that combination goes on the stop-and-call list alongside the ignition bang. Working CO alarms in every sleeping area are the law in BC homes with fuel-burning appliances, and our carbon monoxide guide covers the full safety picture; the rumble chapter of this guide is the reminder that combustion sounds and combustion safety share a driveway.
Clicking: Ignitors, Relays and the Retry Rhythm
Clicking is the furnace speaking in code, and the code is timing. A click-click-click at start-up, with the small combustion blower running and then a pause and another attempt, is the ignition sequence retrying: the control board heard the ignitor, opened the gas valve, and failed to get flame confirmation from the flame sensor within its safety window — so it clicks off, waits, and tries again. That rhythm — try, pause, try, pause, sometimes ending in a lockout where the furnace sulks until power-cycled — is the flame-sensor story told in our short cycling guide, and the sensor is the most common culprit by far. A filmed sensor is cleaned in minutes during a tune-up; a failed ignitor or a gas valve that opens late are the next suspects, and both are metered diagnoses.
The other clicks are electric, and they live at the thermostat and the control board rather than the burner compartment. A rapid chatter from the thermostat or a relay clicking hard enough to hear across the room suggests a control-side fault — a failing relay on the board, a thermostat drawing marginal power, or a low-voltage wire with a nick making and breaking contact. These are annoying rather than dangerous, but they strand furnaces too, and they confuse homeowners because the furnace seems to "try" without commitment. The LED flash code in the furnace's sight window accompanies most of these stories — a pattern of blinks that is the board's own diagnosis of itself — and our error code guide decodes them by brand.
The clicking that is genuinely nothing: a single soft click at each cycle start and stop is the control board and the gas valve doing their jobs at exactly the volume they were designed to, and the tick-tick-tick that trails a cycle after the blower stops is the heat exchanger and ducts contracting as they cool — metal being metal. The diagnostic line is rhythm and repetition: rhythmic retries during the ignition sequence are a service item; one discreet click per state change is simply the machine's punctuation.
Humming But Not Starting: The Capacitor Story
This is the noise that arrives as a complaint about heat rather than a complaint about sound: the thermostat calls, the furnace hums — a determined, electrical, mid-pitch hum from the cabinet — and the blower never turns, or turns once and gives up, and the burners may light and then trip on high limit because no air is moving. The hum is a motor trying to start and failing to develop starting torque, and in a PSC blower motor that torque lives almost entirely in the run capacitor bolted beside it. A capacitor weakens with age and heat, its microfarad rating drifts down from the label, and one November morning the blower wakes up without the oomph to turn itself.
The diagnosis is a two-minute meter job — capacitance read against the label, tolerance typically plus-or-minus six percent — and the repair is one of the best value items in this trade: the capacitor itself is an inexpensive part and the swap lands at the friendly end of the $180 to $350 band, often same-visit from a stocked truck. The temptation we spend this paragraph discouraging: the internet's favourite trick of spinning the blower wheel by hand to "help" the motor start. It technically works, once, briefly, and it is how homeowners meet spinning squirrel cages at speed, along with the loose-fan-blade injuries our industry quietly wins awards for. Hands out of the cabinet; the capacitor is a twenty-minute repair and it is not this week's reason to visit an emergency department.
The adjacent hums, for completeness: a hum from the inducer motor (smaller, higher, near the vent) with the burners failing to light is an inducer or pressure-switch story; a hum with nothing at all running is usually the transformer, which is a quiet electrical fact of life at very low volume and a service call when it graduates to a buzz. And a furnace that hums, starts hard, and then runs with weak registers is telling the longer capacitor-decline story we document in our capacitor replacement guide — the same physics runs the AC side of the system, and the tune-up measures both capacitors while it is there.
Metal on Metal: Shut It Off Now (The One Unambiguous Noise)
Here is the chapter the intro promised: a scraping, grinding, metal-on-metal sound from the furnace cabinet — like a shovel on concrete, or a brake rotor long past its useful life — means the blower wheel is touching something it must never touch. The wheel is loose on its motor shaft and walking; a fin has cracked and is dragging the housing; the motor mounts have failed and let the whole assembly sag a centimetre into the casing. Whatever the specific failure, the physics is identical: rotating steel is machining stationary steel, and every minute of runtime converts repairable into replaceable.
The response is the simplest instruction in this entire guide: thermostat to OFF, furnace switch to OFF, and if you want belt-and-suspenders, the breaker too. Then call. This is not a safety emergency in the gas sense — no combustion problem, nothing to evacuate over — but it is the one noise where continued operation is actively converting a $300-to-$650 repair (wheel re-seat, wheel replacement, or a motor-and-wheel assembly) into a bill that can include the control board, the wiring harness chewed on the way down, and on aging units, the replacement-conversation itself. The scrapers that cost the most are the ones that ran "just until morning."
The honest good news, because this chapter otherwise reads like a horror story: blower-wheel failures are rare, they announce themselves unmistakably, and caught at first scrape they are clean work. We re-seat wheels on their shafts with proper couplings, balance what is balanceable, and measure motor current afterwards to confirm nothing downstream was stressed. The follow-up worth requesting even on a good outcome: a check of what caused it — a bearing that was singing for months, a mount rusted through in a damp North Vancouver crawlspace, a past repair that reused a worn coupling — because the scraper always has a backstory, and the backstory is usually a noise from one of the earlier chapters that got politely ignored.
Vibration and Rattles: Inducers, Panels and Small Sins
The tier of noises below the big six is still worth decoding, because it contains one genuine wear item and a pile of false alarms. The genuine one: the inducer motor — the small combustion blower on every high-efficiency furnace that spins up before ignition and runs the whole burner cycle, moving exhaust through the plastic venting. Its bearings wear like any motor's, and the failure voice is a vibration hum that tracks the burner cycle: starts before ignition, runs with the flame, stops when the burners stop. It is one of the more common high-efficiency repairs we make in the ten-to-fifteen-year window, it sits in the $350 to $650 band installed, and letting it run to seizure risks the pressure-switch cascade that strands furnaces at midnight — the inducer that gets replaced on a Tuesday hum is a bargain next to the one that fails during an arctic outflow.
The false alarms are legion and worth a list: blower-door panels left ajar after a filter change buzz on the cabinet face (the most common "furnace noise" call that resolves itself by closing a latch); loose screws in the sheet metal of the return drop sing a pinpoint rattle that tracks airflow; flex duct connections rubbing on framing make a rhythmic squeak in exactly one room; and objects on the furnace itself — the toolbox, the paint can, the Christmas box that migrated by spring — transmit motor vibration into the floor joists like an amplifier. Our favourite diagnostic advice for rattles: press a hand flat on each panel and duct span while it runs; the one that goes quiet under your palm is your culprit, and half the time the fix is a latch or a screwdriver.
And the noise that is not a fault at all, so it can retire from every worry list: the steady whoosh of a high-efficiency furnace in operation — the inducer and the vent flow together — is the sound of the machine working as designed, and it should be boring. A furnace that has been quietly whooshing for a decade and suddenly seems loud is usually telling you about its environment (a return filter loaded to the point the blower works harder, a new resonance in a loose panel) rather than its internals. The $129 tune-up with its static pressure measurement and motor amp draw is how you get the difference in writing instead of in vibes.
Record It Before You Call (Do This Tonight)
The single highest-value thing you can do for a noisy furnace costs nothing and takes ninety seconds: capture it. Video with sound, phone held near the cabinet (not near — at arm's length; you are documenting, not serenading), through at least one full cycle from thermostat call to blower stop. Include the sight window if the furnace has one, because an LED flash code in the same video as the noise is a two-for-one diagnosis. Then note the three coordinates from chapter one in the file name or a text to yourself: location (cabinet/duct/room), moment (ignition/blower start/whole cycle/shutdown), and rhythm (once/repeating/continuous).
Why this matters more than it sounds like it should: noise is the diagnostic evidence most likely to be gone by the time anyone professional is standing in the basement. The intermittent bang refuses to perform for the technician; the click-at-3-a.m. is shy in daylight; and every dispatcher in this trade has taken the call that ends "well, it is not doing it NOW." A recording converts an intermittent witness into a permanent one — our technicians have diagnosed delayed ignition from a phone video more than once, and it changes what goes on the truck before the visit, which shortens the visit, which saves you the diagnostic time you would otherwise be buying for a stake-out.
Add to the recording, if you can, the context shots: the furnace nameplate (brand, model, serial — the parts lookup starts there), the filter as you last saw it, and any error code the board shows. That package — ninety seconds of video, one nameplate photo, one filter photo — is the difference between "we will send someone to listen" and "we will send someone with the part." It is also, not coincidentally, the exact package our Vancouver furnace repair team requests on booking, for the same reason the guide you are reading is organized by sound: the symptom speaks first, and everyone downstream is just listening well.
- Video with sound through one full cycle — thermostat call to blower stop, phone at arm's length from the cabinet.
- The LED sight window in the same video if the furnace has one — the flash code is a free second opinion.
- A photo of the nameplate: brand, model and serial, because every parts lookup starts there.
- A photo of the filter as you last saw it, because airflow context changes half the diagnoses in this guide.
- A note of the three coordinates: location (cabinet, duct or room), moment (ignition, blower start, whole cycle, shutdown), rhythm (once, repeating, continuous).
Prevention: Why Tune-Ups Are the Quiet Treatment
Every noise in this guide has a pre-noise phase that a tune-up can see and a homeowner cannot. The capacitor is measurable months before the hum — microfarads against label, six percent tolerance, a number on the report. The blower bearings are measurable as amp draw drift before they ever sing. The burners that will bang are visibly filmed at the previous year's service; the inducer that will vibrate shows its wear in run current and the earliest audible texture at start-up. This is the unglamorous pitch for the $129 annual tune-up: it is a noise-prevention appointment disguised as an efficiency appointment, and the combustion analysis it includes is the only instrument in this whole story that reads the burner chapters before your ears have to.
The homeowner share of prevention is short: keep the filter honest (a loaded filter raises static pressure, which raises blower effort, which amplifies every resonance and oil-can in the system); keep the furnace room clear of the amplifier objects from the vibration chapter; and run the system through a full cycle each September before the season starts, standing there listening, so you know its normal before November redefines it. Homes in our snow-and-rain shoulder seasons get one bonus item: verify the exterior vent terminations are clear before the season, because restricted venting shows up first as inducer noise and pressure-switch clicks — the furnace complaining about its breathing, which is a subject our first-cold-snap failure guide covers in full.
For the homes where noise has historical reasons — the oil-can ductwork of a 1980s townhouse, the belt-drive relic in a character home, the bedroom directly above the return drop — the prevention conversation is a design one: duct stiffening, isolation mounts, a blower upgrade that runs slower and quieter, or the variable-speed furnace tier that turns the whole volume knob down at install time. Those conversations start with the same recording-and-nameplate package as the repairs do, and they end with written quotes rather than noise complaints, which is the trajectory every furnace owner deserves.
Which Sound Is Yours Tonight?
Run the sort one more time, because it is the whole guide in one breath. Scraping metal: off now, call now. Bang at ignition: off, call now, gas fitter territory. Rumbling with any smell at the registers: same-day call. Squealing, clicking, humming-with-no-start: this week, metered diagnosis, mostly the $180 to $650 band with the $89 diagnostic credited. Duct bangs, panel rattles, shutdown ticks: business hours and a screwdriver, or the $129 tune-up that absorbs several of these into one visit. And when in doubt, the 24/7 line exists precisely for the 2 a.m. version of that doubt — 604-615-2212, live dispatcher, flat $150 after-hours premium disclosed before the truck rolls, 30 to 45 minute response in the core cities, 45 to 60 across Surrey, Coquitlam, Langley and Delta, 50 to 85 through the valley.
Book the routine version through the form below — include the sound description in your own words, because "like a dying seagull" has genuinely appeared on our work orders and helped — and we will bring the meters, the likely parts and the discipline of people who have heard this entire dictionary spoken by every furnace brand sold in this province since 2010. The quiet you are missing is a known quantity. The price of it is published. And the furnace, for its part, will keep telling you exactly what it needs in the only language it has, which is why you now speak it too.
Frequently Asked Questions
Services That Solve This Faster
Furnace Repair and Noise Diagnosis
Metered diagnosis of every sound in this guide, $89 credited to the repair, most fixes inside the $180-$650 band.
24/7 Emergency Heating
Scraping blowers, ignition booms, no-heat calls: live dispatch at 604-615-2212, flat $150 after-hours premium, 30-45 minute core response.
The $129 Furnace Tune-Up
Combustion analysis, capacitor microfarads, burner cleaning — the quiet-treatment visit that catches noises before they have voices.
Furnace Replacement Quotes
When the noise belongs to a furnace at end-of-life: written flat-rate quotes from $3,900 installed, financing from 7.99%.
Related Guides From Our Team
Furnace Error Codes, Decoded for BC Homeowners — the LED flash tables by brand that pair with every clicking and lockout story.
Furnace Short Cycling: 9 Causes and Real Fixes — the flame-sensor chapter behind most of the clicking-retry noises.
AC and Furnace Capacitor Replacement — the humming-blower story in depth — microfarads, tolerance and the twenty-minute fix.
Why Furnaces Fail on the First Cold Snap in BC — the November failure pattern, part by part, and the tune-up that pre-empts it.
How Long Does a Furnace Last? 15 Real Signs — when a noise belongs to a furnace whose age makes the repair math interesting.
Red Seal certified, licensed gas fitters (BC-PL-2019-4421), $2M insured, 15-plus years on the tools, 12,000-plus jobs across Metro Vancouver since 2010, 4.9 stars from verified reviews. We wrote this guide because Metro Vancouver homeowners deserve the numbers, the code references and the honest trade-offs before anyone touches a wrench or a wallet.
More about our team →Get the Noise Diagnosed by Meter, Not Guess
The $89 diagnostic credited to any repair, flat-rate fixes mostly between $180 and $650, licensed gas fitters under BC-PL-2019-4421, and a live dispatcher at 604-615-2212 around the clock with a flat $150 after-hours premium. Send us the recording — the verdict usually starts before the truck rolls.
The furnace is talking. We speak furnace.
Tell us the sound in your own words — the rhythm, the moment it happens, how long it has been going — and we will send the right meters and likely parts on the first truck. Emergencies (scraping, ignition booms, no heat): 30-45 minute response in the core cities, flat $150 after-hours premium disclosed before dispatch, $89 diagnostic credited to any repair.
Call 604-615-2212 WhatsApp Us