The Honest Answer Up Front
For most homes in Metro Vancouver, the answer is an HRV, and it isn't close. A heat recovery ventilator moves stale air out and fresh air in while handing roughly 55 to 85 percent of the heat from the outgoing stream to the incoming one. An ERV, an energy recovery ventilator, does the same job and also transfers some of the moisture. On the wet coast, where the winter problem is too much indoor water rather than too little, the drier HRV airstream is a feature. Expect to pay $3,500 to $7,500 installed depending on ducting, with ERV hardware running about 10 to 20 percent more than the equivalent HRV.
The ERV earns its premium in the situations BC actually produces: a tightly built home with one or two occupants in a cold valley pocket, a house whose winter air goes Sahara at 20 percent relative humidity with static shocks at every doorknob, or a home out Abbotsford way where sustained freezes push an HRV core through more defrost cycles than anyone wants. This guide walks the physics, the BC climate logic, the energy upgrade math ventilation sits inside, the freeze and defrost behaviour nobody mentions in the brochure, and the honest costs of both machines installed in the twelve cities we serve.
An HRV is not an air filter, not a dehumidifier, and not a heater. It is a heat exchanger with two fans. It can only ever deliver fresh air that is nearly as warm as the air it replaces — and in a coastal winter, that also makes it nearly as dry as the outdoors, which is precisely what a damp BC house needs.
0 typical heat recovery
Mid-band counterflow cores return 70 percent of exhaust heat to the incoming air; 55-85 percent is the honest residential range.
$3,500-$7,500 installed
The real Metro Vancouver band: simplified duct-connect installs near the bottom, fully ducted retrofits near the top.
~90 cfm for a 3-bed home
The ASHRAE 62.2 target for a 2,000 sq ft, three-bedroom house: 3 cfm per 100 sq ft plus 7.5 cfm per person.
What the Machine Actually Does
Two fans run in opposite directions through one plastic core. One fan pushes bathroom-and-general-house air outside; the other pulls outdoor air in, and the two streams pass within a millimetre of each other on opposite sides of thin plastic plates, never mixing. Heat conducts through the plates. On a 5°C February morning, a 70 percent effective core delivers supply air around 16-17°C instead of 5°C, which is the difference between fresh air you feel and fresh air you resent. In summer the exchange runs the other way: the machine can pre-cool incoming 28°C air against 22°C outgoing air, shaving a few degrees off what your cooling system has to remove, a pairing worth remembering if you are already weighing a heat pump installation.
What it does not do is clean the air in the sense most people mean. A ventilator exchanges air; it carries a pair of coarse filters to protect its own core, and a MERV-rated filter can be fitted at the intake, but particulate and smoke filtration is a separate conversation with its own guide. It also does not add heat. The blower motors draw 30-120 watts on low speed, and a balanced system neither heats nor cools your house on balance — it just refuses to throw the baby out with the bathwater the way an open window does. Opening a window in January is a controlled heat donation; an HRV on low speed recovers most of the donation while still giving you the fresh air.
The difference between the two machines is one membrane. An ERV core is built with a material that passes water vapour between the streams as well as heat. An HRV core is plastic that passes heat only, so the moisture you generated cooking, showering and breathing leaves with the exhaust air and is not replaced. That single design difference is the whole HRV-versus-ERV decision, and the next two chapters are just the BC climate applied to it.
The Climate That Decides It: Coast Versus Valley
Metro Vancouver winters are wet and mild. Outdoor air at 5°C and 80 percent relative humidity holds about 4 grams of water per kilogram of air. Indoor air at 21°C and 55 percent relative humidity — the condition a family of four produces by dinnertime in a house with closed windows — holds about 9 grams per kilogram. When you ventilate that house with coastal outdoor air and warm it back up indoors, the incoming air lands near 30 percent relative humidity and pulls the house drier with every air change. On the wet coast that is the point. It is why HRVs solve the condensation-on-windows complaint in a 1970s rancher that is more or less airtight after an insulation and air-sealing upgrade.
Drive up the Fraser Valley to Abbotsford or out past Hope, and the winter script flips. Sustained freezes below -10°C, wood heat, and drier continental air mean indoor humidity crashes through the season, and static shocks at the light switch become a nightly event. That is the home where an ERV's moisture retention pays: it sends the winter humidity you already generated back inside with the supply air instead of dumping it, and it produces less condensate in the core, which means fewer defrost cycles. The same logic applies to any tight new build with one or two occupants: a couple in a Step 3 house generates less moisture than a family of five in a leaky 1972 special, and the ERV keeps what little they make.
| Where you live | Winter reality | Indoor problem | The pick |
|---|---|---|---|
| Vancouver, Burnaby, Richmond, North Shore | 2-8°C and damp most of the season | Condensation, window mould, musty air | HRV — drying is the goal |
| Surrey, Langley, Cloverdale, Maple Ridge | Colder nights, more clear-sky freezes | Condensation, some defrost cycling | HRV, either works |
| Abbotsford, Mission and up the valley | -10°C spells, drier continental air | Dry skin, static, more core frost | ERV, or HRV with good defrost |
| Tight new build (Step 3+), 1-2 occupants | Anywhere in the region | Low internal moisture generation | ERV keeps what little there is |
| Interior-style dry cold (Kamloops, Kelowna) | -15°C and drier than a toast joke | Humidity in the teens, cracked furniture | ERV, clearly |
One honest caveat cuts the other way: if your coastal house is damp because of a wet crawl space, a slab with no vapour barrier, or a family that generates 15 litres of water a day indoors, ventilation alone will not outrun the source. Fix the source first, then size the ventilation to what remains.
Tight Homes, the Step Code, and Why New Builds Need One
Older BC houses ventilated themselves by accident. Air leaked through rim joists, around window rough openings, and up through pot-light holes, so the house changed its air every few hours whether anyone wanted it to or not, and the heating bill paid for the privilege. The BC Energy Step Code ended the accident. Step 3 asks a new home to test at roughly 2.0 air changes per hour at 50 pascals; Steps 4 and 5 push toward 1.5 and 1.0. At those numbers there is no meaningful accidental ventilation left, and a house that gets no mechanical fresh air becomes a chemistry experiment: carbon dioxide climbs past 1,000 ppm in bedrooms overnight, humidity fogs the windows in December, and odours linger like bad relatives.
That is why every airtight new home in the province now ships with a whole-house ventilation system, and why an HRV or ERV is effectively standard equipment in anything built to Step 3 or better. The sizing target the industry uses is ASHRAE 62.2: 3 cfm per 100 square feet of floor area plus 7.5 cfm per person, counting occupants as bedrooms plus one. A 2,000 sq ft three-bedroom works out to 60 cfm for the house plus 30 cfm for four occupants, so a 90 cfm class unit covers it with margin, running on low speed most of the year and boosting for parties, painting days, or a smoky summer week when you want more air changes through a good filter.
If you are renovating an older house toward airtightness instead of building new, the same rule arrives on a delay: every heat pump or envelope upgrade that tightens the shell raises the value of controlled ventilation. The worst outcome is a house sealed halfway, which is the drafty house you paid for plus the stale-house problems you didn't.
Cores, Effectiveness, and the Numbers That Matter
The core is the machine. Residential units use crossflow plastic cores, counterflow cores, or, in ERVs, a membrane or treated-paper core that also passes moisture. Effectiveness is published as a sensible recovery efficiency, and the honest residential band runs from about 55 percent for a small crossflow core to 85 percent for the best counterflow units at low speed. ERVs add a latent figure, how much water vapour crosses the membrane, typically 40 to 70 percent in the better residential units. Buying strategy is simple: within one brand line, pay for the better core and the ECM fan motor, and skip the touchscreens.
| Core type | Heat recovery | Moisture | Care | Found in |
|---|---|---|---|---|
| Crossflow plastic (HRV) | 55-70% | None | Rinse in the sink annually | Compact, budget units |
| Counterflow (HRV) | 70-85% | None | Vacuum, rinse per manual | Premium mid/large units |
| Membrane ERV core | 60-80% | 40-70% latent | Vacuum only, never wet | ERV lines, tight homes |
| Treated-paper ERV | 55-75% | 50-70% latent | Vacuum only, keep dry | Compact ERVs |
| Rotary wheel | 75-90% | Adjustable | Service per schedule | Mostly commercial |
One maintenance detail worth money: plastic HRV cores are washable, so a five-minute annual rinse keeps rated effectiveness for years. Paper ERV cores cannot be washed; a saturated paper core is a mould farm, so they get vacuumed and replaced on schedule. If nobody in the house will do filter and core care, weight the choice toward the washable HRV core and a service plan, because a neglected ventilator quietly stops being a ventilator while still using electricity.
Core Freeze: The Chapter Nobody Puts in the Brochure
An HRV core condenses water out of the outgoing airstream all winter, because 21°C indoor air at 40 percent relative humidity has a dewpoint above the core temperature every time outdoor air sits below about 2°C. That condensate runs to a drain. When the outdoor temperature drops far enough below freezing, roughly sustained -5°C, the cold end of the core chills below 0°C and the condensate freezes on the exhaust-side plates instead of draining. Airflow drops, recovery drops, and the controls notice: the unit runs a defrost cycle, most commonly by recirculating warm supply air through the core for a few minutes per hour, or by briefly closing the outdoor damper. Some smaller units use a tiny preheater on the supply stream.
In Vancouver proper, sustained -5°C happens perhaps 10 to 15 nights a winter; in Abbotsford and up the valley it is 25 to 40 nights, and a cold snap at -15°C will have an HRV defrosting a meaningful share of every hour. None of this is a malfunction; it is the design working as intended, and a correctly sloped condensate line — never a flat run, never an outdoor trap that can ice — keeps it boring. The ERV's advantage here is physics rather than marketing: by moving water vapour across the membrane before it can condense, the ERV produces far less condensate in the first place, so it defrosts less in the same weather. That is the strongest honest argument for ERVs anywhere in BC that freezes hard, and it is why ERVs own the interior market from Kamloops to the Kootenays.
We see more dead HRVs from a frozen, cracked condensate line than from any electrical fault. The line must slope to a drain, and the drain must be inside the building envelope. A trap run through an unheated garage in Abbotsford is a service call we can schedule from the phone number alone.
If your winter plan already includes the pre-winter walkthrough, add two items to it: check the HRV condensate slope, and confirm the exterior hoods are not packed with leaves or snow. Both take five minutes, and both are in the top five causes of "my HRV stopped working" calls.
Fully Ducted Versus Simplified: The Decision That Sets the Price
There are two ways to pipe a ventilator through a house. The fully ducted system runs its own dedicated network: exhaust grilles in each bathroom and the laundry, supply registers in every bedroom and the living areas, and nothing shared with the furnace. It is the best-performing arrangement, it works in houses with no forced-air system at all, and it costs the most, because someone is cutting, insulating and sealing a few hundred feet of small duct through finished space. The simplified arrangement ties the ventilator into the furnace or air handler: the HRV exhausts from a central return duct and dumps its supply into the same return, letting the furnace blower distribute it. It costs half as much to install and performs well when the furnace fan runs on low continuously, and it performs like a rumour when the fan cycles off, because fresh air stops moving with it.
Kitchens get their own rule in both cases: code and good sense put a kitchen on a dedicated range hood exhausted straight outdoors, never through the HRV core, because grease loads a core in months. And if the house has no ducted furnace — baseboard heat, radiant floors, or ductless heads — the fully ducted ventilator is not an upgrade, it is the only option, which is why so many electric-heated Vancouver Specials and laneway houses end up with exactly that layout.
| Layout | Typical installed cost | Best at | Trade-off |
|---|---|---|---|
| Simplified, furnace-connected | $3,500-$4,800 | Homes with ducted furnaces, fan on low | Air quality follows the fan schedule |
| Fully ducted, new construction | $4,500-$6,500 | Step Code builds, any heat type | Needs commissioning time on site |
| Fully ducted, finished-house retrofit | $5,500-$7,500 | Baseboard or radiant homes needing air | Drywall patches, most disruption |
| ERV in any of the above | Add ~10-20% to the unit, not the ducts | Dry-winter sites, low-occupant tight homes | Paper cores need stricter care |
Our Vancouver HVAC crews quote both layouts flat-rate after a look at the attic, the crawlspace and the wall stack, because a 1960s house with a straight two-storey chase and an open attic is a different job than a warren of suites and patched renovations, and pretending otherwise is how quotes go wrong in both directions.
What an Install Actually Costs in BC
The unit is the small line on the invoice. A quality 100-200 cfm HRV with an ECM motor runs $1,200 to $2,600 depending on core and controls; the ERV equivalent adds 10 to 20 percent. The rest of the bill is labour and materials: ducting, insulated to R-4 minimum on any run through unheated space so you are not making cold-weather fog inside your own ducts, exterior hoods with rodent screens, a condensate connection, low-voltage control wiring, and balancing. Permits apply in most municipalities for new ventilation circuits, and we pull them; final pricing is confirmed in writing after the site assessment, because the difference between a clean chase and a finished ceiling full of surprises is the difference between the bottom and the top of the band.
Running cost is the part people enjoy: on continuous low speed a modern unit draws 30-120 watts, so $25 to $75 a year in fan electricity, and it recovers heat that an open window would donate to the Georgia Strait. The filter pair is $15 to $30 per change, quarterly in a normal household. Annual professional service — core cleaning, balance re-check, condensate verification — runs in the $149 to $250 range consistent with the rest of our heating and ventilation service menu, and it is the difference between a ventilator that lasts 15 years and one that gets ripped out at year seven because it got noisy and nobody knew why.
- $3,500-$4,800 — simplified furnace-connected install, HRV, typical ducted-furnace home
- $4,500-$6,500 — fully ducted new-construction install at rough-in stage
- $5,500-$7,500 — fully ducted retrofit through finished space, any heat type
Balancing, and the Combustion Question That Comes With It
A ventilator has two fans, and they must move the same volume. If the supply fan wins, the house runs slightly positive and pushes warm moist air into walls, where BC winters turn it into hidden condensation; if the exhaust fan wins, the house runs negative and pulls outdoor air through every crack, which in a tight house means pulling soil gas, garage air, or fireplace smoke indoors. Balancing is done at commissioning with a flow hood, and a competent installer leaves the numbers on the door or in the manual: target is supply within about 10 percent of exhaust. Socks-on-doors and whistling under exterior doors are the homeowner symptom that balance has drifted, usually a clogged filter on one side, and it is a five-minute fix.
The reason we take it seriously is the appliance in the next paragraph. A surprising share of Metro Vancouver housing still runs atmospheric, natural-draft gas equipment: a water heater with a draft hood in the garage, an older furnace with a pilot light. Those appliances depend on a house that is not under sustained negative pressure. A big kitchen range hood or a dryer can already spill them; adding an unbalanced exhaust-heavy ventilation system does it on a schedule. This is why our commissioning on any home with natural-draft equipment includes a spillage check at the draft hood while fans run, and why the fix is balancing, not abandoning ventilation.
Living With It: Controls, Boosts, and the Summer Question
Run it continuously on low. That is the operating instruction that matters, because a ventilator that runs only when someone remembers is a decoration. The 20-minute-high timer by the master bath, the boost switch for a house full of guests, and a dehumidistat that raises speed when indoor humidity passes a setpoint are the three controls worth having; smartphone apps are optional and, in our service experience, the first thing to stop being checked. In summer the question flips to whether to run it at all: a ventilator exchanges air with the outdoors, so on a 28°C August afternoon it imports heat. Run it on the lowest speed overnight when the coast cools, or shut it during a heat event, and leave it off entirely when wildfire smoke pushes the air quality index past about 7 — the machine has no idea the outside air is the problem, and the intake filter is a coarse dust screen, not a smoke defence.
That last point deserves a sentence of honesty, because we install and service these machines and still have to say it: during the 2023 smoke weeks, the healthiest house was the sealed one with standalone HEPA filtration, not the one dutifully exchanging air through an HRV. Fresh-air machinery is a winter tool in this region; smoke-season strategy is its own topic, and it is mostly about filtration and closed windows. If you are pairing ventilation planning with a bigger mechanical refresh, our heat pump team sizes the two together, because a ventilator's recovery and a heat pump's load are neighbours in the same energy budget.
The Whole Decision, One Table
Ten chapters compressed to the answers people actually need at the kitchen table.
| Question | The honest answer |
|---|---|
| HRV or ERV in Metro Vancouver? | HRV in most homes — wet coast winters make drying a feature, not a bug |
| When does ERV win? | Valley cold pockets, dry-winter sites, tight homes with 1-2 occupants, static-shock houses |
| What does recovery really run? | 55-85% sensible; ERV adds 40-70% of the moisture |
| What does an install cost? | $3,500-$7,500 depending on ducting; ERV adds ~10-20% to the unit only |
| How much airflow do I need? | ASHRAE 62.2: 3 cfm/100 sq ft + 7.5 cfm/person — about 90 cfm for a 2,000 sq ft three-bed |
| Will the core freeze here? | HRV defrost cycles below about -5°C; 10-15 nights a winter in Vancouver, 25-40 in the valley; ERV condensates less |
| How do I run it? | Continuous low speed, boost for crowds and showers, off or minimum during heat events and smoke |
| What maintenance? | Filters quarterly ($15-30), core rinse or vacuum annually, condensate slope check before winter |
| Who balances it? | The installer, with a flow hood, at commissioning — numbers left on the unit |
If your house fogs its windows every December, smells stuffy by bedtime, or was built tight enough that the air goes stale by morning, a ventilator is the machine for that job — and the coast-versus-valley logic above decides which one. Book a site look and we will tell you which, honestly, including when the answer is "fix the crawl space first."
Get a Ventilation Recommendation That Fits Your House
A free estimate covers your home's airtightness era, the ducting options with real prices, the HRV-versus-ERV call for your specific location, and the commissioning numbers in writing. Zero obligation, and if the honest answer is "not this house," you will hear it for free.
Frequently Asked Questions
Services From This Guide
Licensed crews, flat-rate quotes and 24/7 emergency response across the twelve Metro Vancouver cities we serve, from sea-level Richmond out to the Fraser Valley.
Heating & Ventilation
Installs, service and balancing, flat-rate, from a credited $89 diagnostic.
HVAC Vancouver
Ventilation design and commissioning for tight city homes and Specials.
Heat Pumps
Right-sized heat pumps that pair with recovery ventilation, from $6,500 installed.
24/7 Emergency
Around-the-clock response with flat after-hours pricing posted upfront.
Related Guides
Energy-Efficient Upgrades That Pay Off in BC
Where ventilation sits in the ranked return on every upgrade dollar.
WinterWinter Prep for Your Vancouver Home
The seasonal walkthrough that includes your HRV condensate line.
Heat PumpsHeat Pumps in Vancouver: The Complete Guide
Pairing fresh-air machinery with the right heating plant.
We have commissioned and balanced HRVs and ERVs in everything from 1960s Vancouver Specials converted off baseboard heat to Step 3 laneway houses, and the coast-versus-valley logic in this guide comes from reading the condensate lines, not the brochures. Red Seal certified, licensed gas fitters BC-PL-2019-4421, 12,000-plus jobs across Metro Vancouver since 2010. To book instead of DIY, see furnace maintenance in Delta — same-day across the city.
More about our team →Get Your Ventilation Plan and Quote
A free estimate covers your home's leakage era, HRV-versus-ERV for your location, both ducting layouts priced in writing, and the commissioning numbers you keep. Zero obligation — if the answer is 'not this house,' you hear that for free too. If you would rather hand this to a pro, our heating & furnace services pages cover Metro Vancouver.