Gravity drains keep draining and city water keeps flowing, but every pump, blower and igniter in your home stops the moment the grid does. This is the honest outage map for BC homes: the first five minutes, the sump-pump problem, heating and hot water without power, well-tank math, the freeze ladder, the restart sequence and the generator truth.

Metro Vancouver home at dusk during a power outage with flashlight glow in the window
The outage question is always the same two questions: what still works, and what do I touch first.
Chapter 1

The Honest Answer Up Front

When the grid goes down in Metro Vancouver, your plumbing keeps half its promises. Gravity drains keep draining, and city water pressure keeps cold water flowing to most taps on most floors, which is why a candlelit evening usually still includes a working kitchen sink. What stops is everything with a motor, a pump or a circuit board: furnaces and their blowers, heat pumps, boilers with circulator pumps, tankless water heaters, sump pumps, well pumps, and the igniters and vent fans that modern gas appliances depend on.

The honest version of this guide is not survivalist. BC outages are usually measured in hours, and a house that knows what keeps working coasts through them comfortably. The two exceptions that earn chapters of their own are the sump pump in a wet-season basement and the heating system during an arctic-outflow week in January, because those are the outages that convert an inconvenience into a flood or a freeze. Everything else here is the triage order for the first five minutes, the restart sequence when the lights return, and the honest generator conversation that follows.

Our 24/7 emergency dispatch runs the storms with you, and the field notes in this guide come from the windstorm and freeze-outage calls our crews have answered across the region since 2010. The through-line of every one of those calls: the houses that fared best were not the ones with the most equipment, they were the ones that knew which breaker belonged to which machine and which valve to close when the sump went quiet.

An outage does not break your home. What you do in the first five minutes, and again when the power returns, decides whether it stays that way.

0 of tank heat

A full, hot, well-insulated tank still holds useful warmth a day or two into an outage. Conserve it in drawn cups, not showers.

0 diagnostic, credited

The post-outage visit for a furnace, pump or tank that will not restart, deducted from any repair booked the same day.

0 jobs since 2010

Storm-night and freeze-week calls that shaped the restart sequence in this guide.

0 stars, 26 reviews

Homeowners rating the storm response flat, on time and exactly as quoted.

Chapter 2

The First Five Minutes: Triage in the Dark

Outage mistakes happen in the first five minutes, and they cluster around two instincts: flipping every switch in reach, and running major appliances the instant the grid flickers back. The triage order below is short on purpose, and it ends with the one prep task that pays for itself: knowing your breakers by name.

1

Lights, then look

Flashlight from the known drawer, not a phone you will need later. Confirm the outage is the block and not your main breaker by checking whether streetlights or neighbours have power.

2

Protect the big three

Set the furnace or heat pump thermostat to off, switch the sump pump to its battery system if it has one, and unplug the garage-door opener and any pump you cannot switch at the panel. This prevents both surge damage at restart and dry-running equipment.

3

Run the water you will need

Fill a kettle and a pot while pressure is known-good, and flush once to confirm drains are working. If you are on a well, do this immediately, because the pressure tank only holds a limited draw.

4

Note the sump pit level

If you have a sump, glance at the pit now and again every hour in wet weather. The float rising toward the slab is the early warning that the battery backup, the spare pump or the emergency call is next.

5

Then leave it alone

Nothing else in the first five minutes needs doing. Doors closed keep fridge cold, water heater tanks are already full of stored heat, and the restart sequence in Chapter 9 is where the next decisions belong.

The single best prep task is the breaker labelling session from the shutoff-map school of home ownership: two people, one at the panel, one at each appliance, until the furnace, air handler, sump, well pump, hot water tank and laundry are labelled in ink. The session takes thirty minutes, and it converts every future outage from a guessing game into a checklist. For the deeper plumbing-side emergency training, the emergency plumbing guide for Vancouver homes covers the flood scenarios this triage feeds into.

Chapter 3

What Keeps Working Without Power

The systems map below is the heart of the honest answer, and it rewards a read now rather than at candle-time. The pattern to see: water keeps moving downhill, but nothing moves uphill without a pump, and nothing burns safely without a fan or an igniter in modern equipment.

SystemWithout powerThe honest note
Kitchen and bath drainsWorkingGravity is the utility that never fails. Flush toilets once to confirm, then use them normally; the tank refills as long as city pressure holds.
Cold water, city supplyWorking on most floorsMunicipal pressure serves low and mid floors without help. High floors of tall buildings ride rooftop or booster pumps, which stop, and stratas post their own protocol.
Hot water, tank typeStored heat, no recoveryA full tank holds useful heat for 24 to 48 hours. Draw it sparingly, and see Chapter 6 for the gas-pilot exceptions.
Hot water, tanklessStoppedElectric ignition, vent fan and flow sensing all need power. No power, no hot water, full stop.
Furnace, gas, modernStoppedThe inducer fan, igniter and blower are electric. A standing-pilot gravity furnace from the pre-1970s is the rare exception that keeps heating.
Heat pump or air conditionerStoppedCompressor and fans are electric; nothing to manage here but the thermostat and the restart sequence.
Boiler, hydronicUsually stoppedBurner controls and circulator pumps are electric. Some gravity-circulated legacy systems keep a trickle of heat, but no modern BC boiler heats without power.
Sump pumpStoppedThe one true emergency candidate. Wet-season basements need a battery backup or a monitored alarm, covered in Chapter 4.
Well pump and pressure tankLimited draw, then stoppedThe tank holds a few pressure-fed buckets to a few bathtubs depending on size. Conserve immediately, Chapter 7.
Gas fireplace, modernStopped, usuallyMost use electric fans and electronic ignition; standing-pilot millivolt valve models are the exception and keep radiating without power.
Gas stove and cooktopUsually workingStanding pilots light; electronic-ignition ranges can be match-lit per the manufacturer instructions, with caution for ovens, which are often blocked by design.

Two rows carry most of the region's outage anxiety. The hot-water answer for a tank is conservation, one cup at a time for warm water rather than a shower that drains the tank's core heat in eight minutes. The furnace answer is layers and house-holding, because a modern BC house in October coasts a surprisingly long time if doors stay shut, and the January case is its own chapter below.

Chapter 4

Sump Pumps: The Silent Casualty

Every other system in this table announces itself when it stops. The sump pump stops silently, which is precisely the problem: in a November atmospheric river or a February thaw, a powerless sump converts a wet-season basement from a nuisance into a claim in the hours the family spends upstairs with candles. The homes that coast through outages are the ones that treated the sump as emergency infrastructure, not a mystery box in a hole.

The honest readiness ladder has four rungs. The floor is a working pump and a check valve, so the pit empties and the discharge does not backflow when the pump pauses. The first rung is a high-water alarm, battery-operated and loud enough to hear through a floor, ten dollars of early warning that the water has reached the point where minutes matter. The second rung is a battery backup pump, which buys hours to a day of intermittent duty against the pit inflow. The top rung, common in the high-water-table pockets our crews serve, is a water-powered backup, which uses city pressure to pump and runs as long as the municipal supply does, at the cost of some water usage. Each rung is cheap relative to the first hour of a restoration claim.

Two habits multiply whatever rung you own. The quarterly test, a bucket of water into the pit to confirm the float trips and the pump empties it, tells you the machine works before the outage tests it. And the breaker label from Chapter 2 pays off here more than anywhere: a sump that tripped its GFCI during a power event is restored with one labelled flip at the panel, and a surprising share of dead-sump calls we answer are GFCI trips wearing outage costumes. Homes built on the old creek beds and low benches of the region should assume their pits fill fastest, and act accordingly.

The sump pump is the only appliance in the house that fails silently while costing five figures an hour. Alarm it, back it up, and test it when the sun is out.

Chapter 5

Heating When the Grid Is Down

A modern gas furnace without electricity is a metal box with gas behind a valve, and the honest answer to the every-winter question, can I run it anyway, is no, not by any safe method. The inducer fan that clears the flue, the igniter, the blower that moves heat into the rooms, and on high-efficiency units the condensate drain, all need power. The failure modes of improvising around this, from blocked flues to cooked heat exchangers, are the reasons the answer stays no, and our furnace technicians in Vancouver spend the first day after every major outage explaining it kindly.

1

Hold heat, do not chase it

A house with closed doors, drawn drapes and a family in one or two rooms coasts for hours against BC outside temperatures, far longer than most homeowners expect. Interior rooms beat perimeter rooms, and the top floor of a house holds warmth the longest.

2

Dress the building

Towels at exterior door bases, blankets over large windows, and cabinet doors open under sinks on exterior walls to keep mild warm air reaching the pipes. The freeze defence and the comfort defence are the same moves.

3

Water trickle on the freeze line

If the outage stretches into a cold night and the house is trending below roughly 13 to 15 degrees indoors, run the cold tap farthest from the main at a pencil-thin stream, because moving city water is the cheapest antifreeze a home owns.

4

Watch the long-cold case

Outflow events can pair minus-ten nights with multi-day outages. That is the threshold where the drain-down decision in Chapter 8 stops being theoretical, and an hour of draining beats a burst pipe and the $280 to $850 repair plus the flood behind it.

The electric fallbacks deserve one honest paragraph each. Baseboard heaters are on the grid by definition, so they offer nothing here. Ventless fuel heaters of the camp and catalytic kinds are not a BC heating answer for occupied rooms, full stop, and the same paragraph covers barbecue and hibachi solutions: outdoor equipment stays outdoors, because carbon monoxide is the outage fatality this region actually records. If you smell gas at any point during any of this, the protocol is unchanged: evacuate everyone, call FortisBC at 1-800-663-9911 or 911 from outside, and the plumber is never the first call.

Chapter 6

Water Heaters: Tank, Tankless and the Pilot Question

The hot-water picture during an outage splits cleanly along the tank line, with a gas wrinkle inside it. A tank-type water heater, gas or electric, is a thermos: forty to sixty gallons of already-hot water that loses heat slowly and keeps serving for a day or two, no power required to dispense it. A tankless unit is a computer with a burner, ignition, vent fan and flow sensors all electric, and it produces nothing until the grid returns.

The gas wrinkle is the pilot and the vent. An older natural-draft gas tank with a standing pilot keeps its pilot and, in most models, can even keep heating a new tank of cold water without electricity, which is why some homes discover a strange luxury: hot showers during an outage. Power-vented and high-efficiency gas tanks, the ones with a fan on top, stop heating when the fan stops, though they still dispense the stored heat. Electric tanks are pure stored heat, and forty gallons drawn in cups lasts a family a surprisingly civilized day and a half.

Two outage-era habits protect the machine as well as the comfort. Turn the tank's gas control to pilot or vacation rather than off if you expect a multi-day outage, so relighting is a knob rather than a technician, and keep the stored-heat discipline: short draws for warm water, lid on the kettle, and the shower waits for the grid. After a long outage, a tank that will not relight or an element-cycled electric tank lands in the $180 to $450 water heater repair band, with the $89 diagnostic credited to the repair, and our Surrey water heater crews can usually book those restart visits the same day the region's power does.

Homeowner checking a power-vented gas water heater and its vent fan after a power outage
After the grid returns: the tank that reheats and the tank that sulks are separated by one fan and one breaker label.
Chapter 7

Well Systems: The Pressure Tank Math

Homes on wells feel outages first and hardest, because the well pump is the water utility. What the house runs on, for the first minutes to hours, is the pressure tank: a steel or fibreglass bladder tank holding a finite volume of pressurized water, and every draw spends it. The math is simple and ungenerous. A small tank yields a bathtub or two of full-flow water; a large modern one can push the household through most of a day of conservative use, toilet flushes, kettle fills and quick hand-washes, before the sputtering starts.

The well playbook is therefore front-loaded. At the first sign of an outage: fill drinking containers immediately, fill the kettle, and fill one large pot, in that order, while pressure is known-good. Then shift the household to conservation mode, no laundry, no dishwasher, and short-flush habits if the family is large. Keep one tap cracked slightly open in a low fixture to signal when the tank is empty: the sputter that announces air is the cue to close everything and wait for power, because dry-running a submersible pump that comes back on against closed taps is how pressure switches and controls take damage.

The restart rules matter even more on wells. When power returns, let the system pressure build for a few minutes before opening taps wide, because the pump may have been mid-cycle when the outage hit and the pressure switch will finish that thought with the grid's help. A pump that runs but builds no pressure, short-cycles constantly, or blows breakers is a call for diagnosis, and the eastern-valley homes our Abbotsford and Fraser Valley crews serve know this chapter by heart, from Sumas Prairie farms to hillside acreage, where the pressure tank is the whole water company and the generator question in Chapter 10 is answered yes more often than anywhere else in the region.

Chapter 8

Freezing Risk When the Outage Is Long and Cold

The scenario that earns planning is not the October windstorm, it is the January pairing of an arctic outflow with a grid failure, cold that would eventually freeze pipes meeting a house with no heat to hold against it. Houses lose interior heat on their own schedule: well-insulated stock can hold above freezing for one to two cold days, older character homes can drop toward the danger zone within a single minus-ten night. The freeze risk concentrates where it always does, in the pipes nearest the outdoors: hose bibs, garage and crawlspace lines, kitchen sinks on exterior walls, and the condensate drains of high-efficiency furnaces.

The defence ladder for a long, cold outage runs in steps, and each step costs less than the one it prevents. Hold heat in the house with the Chapter 5 moves. Keep the pencil-thin trickle running at the farthest cold tap, because city water at a few degrees above freezing carries an enormous amount of anti-free energy through the pipe per hour. Open cabinet doors and garage access hatches so the house's stored warmth reaches the plumbing. Wrap the most exposed runs in towels or blankets for the night. And if the outage is confirmed multi-day into a cold snap, with the house trending colder by the hour, the last rung is the one nobody enjoys: the drain-down, closing the main valve, shutting the water heater's gas to pilot, opening every low tap and draining the system's vulnerable water out through a laundry tub or basement drain, then leaving taps open for the return.

The economics of the drain-down are one honest paragraph. It costs an hour of cold work and a full kettle of air-lock bleeding when power returns. The pipe it prevents bursting costs the $280 to $850 repair, the after-hours timing it almost certainly arrives with at the $150 flat premium, and the restoration claim behind it when the thawed pipe lets go in a house nobody is watching. For the full prevention calendar, bib draining, insulation and the outflow-season checklist that keeps the grid-up version of winter safe too, the winter prep guide for Vancouver homes is the companion piece to this chapter, written for exactly these weeks.

Emergency plumber responding to a burst pipe during a winter power outage in Metro Vancouver
The January pairing: no heat, no light, and a crawlspace line that let go at minus nine. The drain-down exists to prevent this photograph.
Chapter 9

When the Power Returns: The Restart Sequence

The restart is where outages quietly do their damage. Grid power returns with sags and surges, every compressor and pump in the neighbourhood asks for start current at the same moment, and the appliances that take damage are the ones switched on and forgotten. The sequence below is the one our technicians would run in your house, and it takes ten minutes.

1

Wait five minutes before the big machines

Give the grid a few minutes to stabilize after the neighbourhood-wide rush. This single pause prevents most surge damage, and it is the cheapest insurance in this guide.

2

Restore the panel in order

Reset any tripped breakers one at a time, sump and well or booster pumps first, water heater second, furnace and air handler last. One at a time means the guilty circuit, if there is one, identifies itself alone.

3

Prove the sump before you trust it

Watch one full cycle with the battery backup disengaged if it allows, and confirm the check valve holds the pit dry after the pump stops. A sump that runs but does not empty its pit is a call, not a success.

4

Reboot the thermostat, then the furnace

Modern thermostats and control boards benefit from a clean restart: thermostat to off, power restored, wait a minute, thermostat to heat and normal setpoint. The furnace should prove a full cycle, igniter to blower to burner-off, without unusual noise or short cycles.

5

Listen once, everywhere

Walk the house with your ears open. A well pump short-cycling, a furnace locking out after two tries, a sump running dry, a water heater refusing to relight: each of these is the $89 credited diagnostic before it becomes the repair.

One furnace-specific note from the storm files: lockouts are normal protection, not proof of damage. Most modern furnaces try ignition a set number of times and then wait, safely, for a reset or a technician, and a large share of next-morning no-heat calls after an outage are control-board lockouts from the outage itself rather than broken parts. Follow the manufacturer's reset once if you are comfortable, and if the furnace refuses a clean second start, that is the diagnostic visit, with furnace repair running $180 to $650 depending on what the board and the igniter turn out to need.

Chapter 10

Generators, Honestly

The generator conversation splits into the portable question and the standby question, and both answers run through one gate: the transfer switch, installed by a licensed electrician, which isolates your house from the grid while the generator feeds it. Backfeeding a panel through a dryer outlet is the dangerous folk practice this paragraph exists to close out, lethal to linemen and to the generator and frequently to the panel besides. There is no honest version of it.

ApproachWhat it honestly buysThe catch
Battery power stationHours of sump duty, phones, fridge, lights. Silent, indoor-safe, rechargeableFinite. Size to the sump, the device that earns the watts, not the popcorn maker.
Portable generator, cords onlyTargeted power: a sump, a fridge, a furnace via a furnace cord kit, by extension cordOutdoor placement only, a full 6-plus metres from any door or window, CO alarm indoors. Manual, noisy, fuelling discipline.
Portable plus transfer switchSelected house circuits, including the furnace, from one outdoor inlet, no backfeedLicensed electrician install, permits, and a generator sized to the selected loads, honestly calculated.
Standby generator, autoWhole-house or essentials coverage that starts itselfThe five-figure project. Gas sizing, siting and permits, and it earns its cost in the country, on wells, or where outages repeat.

Carbon monoxide gets its own paragraph because it is the outage's quiet killer. Generators run outdoors, far from openings, never in garages or under eaves, and the house needs working CO alarms before it needs any generator at all. The same paragraph carries the standing gas rule for the whole grid-down week: if you smell gas near the meter, the fireplace or any appliance, evacuate everyone, call FortisBC at 1-800-663-9911 or 911 from outside, and never the plumber first. Our gas fitters take those calls second, after the utility has made the scene safe, which is exactly where a licensed crew belongs in that sequence.

For sizing honesty, the loads that matter in BC outages are the sump, the fridge, and either the furnace or a heat pump air handler, in that order of urgency. A portable unit honestly rated to run the sump plus the fridge continuously, with the furnace added by transfer switch on the coldest night of the year, is the sweet spot for most Metro Vancouver homes, and the electrician's load calculation during the transfer-switch quote is the moment of truth for every generator advertisement you have ever read. The financing page on this site exists for the standby end of the ladder, and the honest sizing conversation is free either way.

Chapter 12

The Outage Cheat Sheet

The whole guide as one card. Photograph this section for the drawer with the flashlight.

WhenWhat happens
First five minutesFlashlight, confirm the block is out, thermostat to off, sump to battery, fill kettle and pot, glance at the pit
The hours in betweenDoors closed, stored heat held, hot water drawn in cups, pit checked hourly in wet weather
Cold-night escalationTrickle the farthest cold tap, cabinet doors open, exposed pipes wrapped; drain-down if multi-day cold is confirmed
Any gas smell, any timeEvacuate everyone, FortisBC 1-800-663-9911 or 911 from outside, never the plumber first
When power returnsFive patient minutes, breakers one at a time, pumps first, furnace last, then one full quiet cycle
Machine will not restartOne reset per manufacturer, then the $89 diagnostic, credited to the repair; furnace $180 to $650, water heater $180 to $450
After-hours storm callsThe $150 flat premium, posted in advance, never a meter and never a multiplier
Before the next outageLabel the breakers in ink, test the sump quarterly, alarm the pit, and put the generator question to a licensed electrician

The grid fails gracefully to whoever prepared for it: five minutes of triage, one honest restart, and a basement that stayed dry because the sump had a plan before the power did.

Quick answers

Frequently Asked Questions

Almost never, and not by any safe improvisation. Modern gas furnaces use an inducer fan to clear the flue, an electric igniter and a blower to move heat into the rooms, and on high-efficiency units a condensate drain that all depend on electricity, so a furnace without power is a sealed box with gas behind a valve. The rare exceptions are standing-pilot gravity furnaces from the pre-1970s, which can keep radiating a trickle of heat. Attempts to force a modern furnace to run without its fans risk blocked-flue carbon monoxide and cooked heat exchangers, which is why the honest outage answer for heating is holding heat in the house and layers, not bypassing safeties.
A full, hot, well-insulated tank holds useful warmth for roughly 24 to 48 hours, with the practical limit being how fast the household spends it. Draw water in cups for warm washing rather than in showers, which strip the tank's core heat in minutes, and a family can stay civilized through most BC outages on stored hot water alone. Tankless water heaters are the opposite case: ignition, vent fan and flow sensing are all electric, so a tankless produces nothing until the grid returns. Gas tanks with standing pilots are the quiet luxury in between, since many keep heating new water without electricity, while power-vented tanks with fans dispense their stored heat but stop reheating.
It stops, silently, which is the entire problem in wet weather. The pit keeps filling from ground and drainage water while the float rises toward the slab, and an unwatched, unpowered sump in a November storm or a February thaw can convert a basement into an insurance claim in a few hours. The readiness ladder is cheap relative to that: a battery-powered high-water alarm first, a battery backup pump that buys hours to a day of intermittent duty second, and for high-inflow homes a water-powered backup that runs on city pressure. Quarterly, pour a bucket of water into the pit and confirm the float trips and the pit empties, and confirm the pump's breaker and GFCI are labelled, because a tripped GFCI is the most common dead sump wearing an outage costume.
Work the ladder in order, because each step is cheaper than the one it prevents. Hold heat in the house first: doors closed, drapes drawn, family concentrated in one or two rooms. Run a pencil-thin trickle of cold water at the tap farthest from the main, because moving city water carries a large amount of anti-free energy through the pipe. Open cabinet doors under sinks on exterior walls and open garage or crawlspace access so the house's stored warmth reaches the plumbing, and wrap the most exposed runs in towels for the night. If the outage is confirmed multi-day into an arctic-outflow period and the house is trending colder by the hour, the final rung is the drain-down: close the main valve, set the water heater gas control to pilot, open every low tap and drain the vulnerable water out. That hour of cold work beats a burst pipe repair of $280 to $850 plus the flood behind it.
Yes, but only through a transfer switch installed by a licensed electrician, never through a backfed dryer outlet, which is lethal to utility linemen and a fire risk at the panel. A transfer switch isolates the house from the grid and lets selected circuits, including the furnace, run safely from one outdoor inlet. The generator itself lives outdoors, a full 6-plus metres from doors and windows, never in a garage or under eaves, and the house needs working carbon monoxide alarms before it needs any generator at all. The honest sizing conversation happens during the electrician's load calculation: the sump, the fridge and the furnace are the loads that matter in a BC outage, in that order. And if you ever smell gas near the generator, the meter or any appliance, evacuate everyone, call FortisBC at 1-800-663-9911 or 911 from outside, and never the plumber first.
Written by the BC Home Service Team

Red Seal certified, licensed gas fitters (BC-PL-2019-4421), $2M insured and 15-plus years in the field, with more than 12,000 jobs completed across Metro Vancouver since 2010 and a 5.0-star rating across 26 Google reviews. Red Seal certified, licensed gas fitters (BC-PL-2019-4421), $2M insured and 15-plus years in the field, with more than 12,000 jobs completed across Metro Vancouver since 2010 and a 5.0-star rating across 26 Google reviews. We wrote this guide because the outage damage we are called to, frozen crawlspace lines, dry-run pumps and lockout-stuck furnaces, is almost all preventable by a labelled panel, a tested sump and ten patient minutes at restart, and teaching that costs everyone less than the alternative. To book instead of DIY, see 24/7 emergency plumber in Burnaby — same-day across the city.

More about our team →
Free Estimate

Storm Left Something Broken?

Book the $89 diagnostic (credited to any repair) or a same-day restart visit with a Red Seal technician. You get the machine diagnosed, a flat written price for any repair, furnace work from $180 to $650 and water heater work from $180 to $450, and a 2-year workmanship warranty when we do the job. Zero obligation, same-day service on most calls. Related reading: Heating Your BC Home During a Power Outage. If you would rather hand this to a pro, our 24/7 emergency services pages cover Metro Vancouver.

Furnace or sump dead after the storm?

Post-outage calls are answered 24/7 with live dispatch and the $150 flat after-hours premium posted in advance. Daytime? The $89 diagnostic is credited to the repair and usually same-day in Vancouver, Burnaby and Surrey.

Call 604-615-2212 WhatsApp Us
Licensed gas fitters, Technical Safety BC permitted installs
10-year parts warranties registered for you
Financing from 7.99% with approved credit
24/7 emergency line, average 45-minute response
Call Now Free Quote