A heat pump that runs but won't warm the house is a different animal from a furnace failure — some of the 'symptoms' are normal cold-weather behaviour, and some of the real faults are invisible without gauges. This guide separates the two for BC homeowners, in the order our repair crews find them, with the 2026 repair prices we actually charge.

Heat Pump Not Heating in Winter? BC Causes & Fixes
Cold-climate heat pumps keep heating through BC outflow snaps — until defrost, refrigerant or control faults get in the way.
Chapter 1

Normal Winter Behaviour vs a Real Fault

Two winter behaviours worry homeowners who did nothing wrong. First, supply air from a heat pump feels cool to the skin even when it is 35-45°C and heating properly — compared to a furnace's 55°C blast, that reads as 'cold' but is doing the job. Second, defrost: every 30-90 minutes in damp near-zero weather the unit reverses, blows cool air indoors for three to ten minutes and steams outdoors. Both are design, not failure — the full mechanics are in our defrost and ice guide.

The real-fault signatures are different: air that never warms across an entire cycle, the outdoor unit running non-stop without catching up, breaker trips at startup, error codes on the controller, or indoor temp sliding despite the thermostat calling. Those need instruments, and guessing parts without gauges is how a $180 fix becomes a $1,800 compressor.

Chapter 2

The Auxiliary Heat That Never Kicks In

When a cold-climate unit's capacity dips during an outflow snap, the electric auxiliary (backup) strips carry the gap. If the strips never engage, the house falls behind exactly when it is coldest — a complaint we take every January from Abbotsford to Chilliwack. Causes range from a burned strip element to a failed sequencer or a control board that stopped calling for aux. Strip element and sequencer repairs run $180-$650 installed, and the diagnostic is $89, credited to the repair.

A thermostat set to EM HEAT accidentally produces the opposite surprise — strips only, compressor off — with an electricity bill to match. Check the mode before you book anything; it is the heat-pump equivalent of the furnace wall switch. If the mode is right and the strips still never stage in, that is a meter-and-sequencer diagnosis our Surrey heat pump repair crews can run in one visit.

Chapter 3

Low Charge and the Long Run Times

A slow refrigerant leak shows up as longer and longer run cycles for the same comfort, then lukewarm air at the registers, then ice on the outdoor coil in weather that should not produce it. Low charge also drops the coil temperature and triggers defrost cycles that never terminate properly. Finding and sealing a leak, then recharging to the nameplate charge, is gauge work: pressures, superheat and subcooling tell the story. Repair runs $180-$650 for the common leaks at flare nuts and service valves; a coil replacement is a quote conversation.

Never accept a top-up as a repair. Refrigerant escaping into the atmosphere is a regulated substance, and a system recharged without leak repair will be low again by the same time next winter — you pay twice for the same fault. A proper repair pressure-tests, seals, evacuates and recharges by weight, with the numbers written on the invoice.

Chapter 4

Ice, Snow Burial and the Coil You Can't See

BC winters bury outdoor units two ways: Fraser Valley snowfall drifting over the coil, and a roofline dropping a slab of snow right onto the fan. A buried or packed unit starves airflow, ices the coil and trips into defrost (or high-pressure lockout) repeatedly. Keep 45-60 cm clear on all sides and above, sweep drifts gently, and never chip ice off a coil — the fins and refrigerant lines take damage instantly.

The failure that hides under the snow is a failed defrost termination: the unit stays in defrost too long or never enters it, and the coil builds a glacier. Thermistors and defrost boards are stock parts, $180-$450 installed. If your unit is a glacier factory this winter after years of clean operation, book the diagnostic before the next cold snap stress-tests it again.

Chapter 5

Sizing, Balance Points and Expectations

Every heat pump has a balance point — the outdoor temperature where its output equals the house's heat loss. A properly sized cold-climate unit in Metro Vancouver holds that point below -10°C; an undersized or older unit gives up near -2°C and leans on strips, and an oversized one short-cycles and dies early. If your system has struggled since installation day rather than this month, the honest fix might be sizing, not parts. Our heat pump installation pages cover cold-climate sizing, and replacements start from $6,500 with CleanBC rebates worth up to $16,000 on fuel-switching retrofits.

Chapter 6

When to Call, and What It Costs

Book the diagnostic when air never warms across a full cycle, error codes appear, breakers trip at startup, ice builds abnormally, or the house falls behind on the coldest nights despite normal runtime. The diagnostic is $89 credited to any repair; typical heat pump repairs run $180-$650; defrost boards and thermistors $180-$450; capacitor and contactor $180-$350; compressor replacements $1,800-$2,800 or a replace-versus-repair conversation. After-hours no-heat calls add one flat $150 premium, disclosed before dispatch — same structure every day of the week.

Quick answers

The Heat-Pump-Not-Heating Cheat Sheet

Symptom to cause to cost, the way the January call actually goes.

What you're seeingLikely cause and real cost
Cool-feeling air, house holds tempNormal heat-pump supply air — no repair
3-10 min cool air bursts, outdoor steamDefrost cycle — normal, no repair
Never warms a full cycle, long runtimesLow refrigerant charge — find/fix leak $180-$650
Falls behind only on coldest nightsAux strips not staging in — $180-$650
Outdoor unit a glacierFailed defrost board/thermistor $180-$450, or buried coil
Trips breaker at startupCapacitor/contactor $180-$350, or compressor
Struggled since install daySizing/balance point — quote conversation, from $6,500

One line to keep: defrost is normal, cool-feeling air is normal, never-warming air is not — and the $89 diagnostic separates them with gauges instead of guesses.

Book a Heat Pump Heating Diagnostic

A $89 diagnostic credited to any repair, gauge-checked answers instead of parts-guessing, and flat-rate pricing in writing before work begins. If you are troubleshooting this right now, Sump Pump Not Working? Before It Rains maps the causes and fixes.

Quick answers

Frequently Asked Questions

Briefly, during defrost — that is normal and required. A heat pump also delivers 35-45°C air that feels cool to the hand but heats properly. Air that never warms across an entire cycle is a fault, most often low refrigerant charge, a failed defrost cycle or backup strips that never engage.
Defrost is periodic: the outdoor fan stops, the coil steams, indoor air goes cool for three to ten minutes, then everything returns. Failure is continuous: lukewarm air all day, runtimes that never end, ice that keeps growing, or error codes. If cool air lasts minutes it is defrost; if it lasts hours, book the $89 diagnostic.
The diagnostic is $89, credited to any completed repair. Common fixes: refrigerant leak find/seal/recharge $180-$650, defrost board or sensor $180-$450, aux heat strips and sequencers $180-$650, capacitor or contactor $180-$350, compressor $1,800-$2,800. After-hours calls add one flat $150 premium.
Only for a diagnosed compressor failure or as a stopgap while awaiting repair — EM HEAT runs the electric strips alone, which costs roughly two to three times more per unit of heat than the compressor. Cold-climate units are built to run normally through BC's coldest snaps with aux support staged in automatically.
A properly sized cold-climate heat pump holds most Metro Vancouver houses at design temperature and below, with aux strips covering the deepest outflow hours. Units without cold-climate ratings lose capacity faster and lean on strips more. If your home falls behind every cold snap, the answer is usually sizing or charge — not weather.
The 24/7 line at 604-615-2212 is answered by a live dispatcher, with typical arrival of 30-45 minutes in Vancouver, Burnaby and New Westminster and 45-60 minutes in Surrey, Langley and Delta. After-hours calls carry one flat $150 premium, disclosed before the van rolls.
Written by the BC Home Service Team

BC Home Service is a Metro Vancouver heating, cooling and plumbing crew: Red Seal certified, licensed gas fitters BC-PL-2019-4421, 12,000+ jobs since 2010 across twelve cities, 26 five-star Google reviews. This guide is written from our own flat-rate job history, with the numbers we actually charge. The causes and fixes are laid out step by step in Furnace Not Heating? 9 Fixes Vancouver Homeowners Can Try First. To book instead of DIY, see heat pump repair in Burnaby — same-day across the city.

More about our team →
Free Estimate

Get a Heat Pump Repair Quote

A free estimate covers a $89 diagnostic credited to the fix, flat-rate repair options for your actual system, and CleanBC guidance if replacement math wins. Written pricing, zero obligation. For the full BC price breakdown, see Baseboard Heating vs Heat Pump: The BC Math. If you would rather hand this to a pro, our heat pump services pages cover Metro Vancouver.

House falling behind tonight?

24/7 no-heat response with a flat $150 after-hours premium posted in advance, and the $89 diagnostic credited to any repair. Outflow snaps are exactly when heat pumps earn their keep.

Call 604-615-2212 WhatsApp Us
Flat-rate, line-item quotes, no surprises
CleanBC rebate paperwork handled on installs
Financing from 7.99% with approved credit
2-year workmanship warranty in writing
Call Now Free Quote